Air handling prepares fresh air before it is supplied: filtration and, when the project needs it, heating or cooling of that air in a unit. It is not a bathroom extractor, smoke control, or a split that only sets the temperature of one room.

AEROVENTIS studies it for villas, buildings and new premises in Casablanca, Mohammedia, Bouskoura, Tamaris, Zenata, Rabat and Marrakech. The fresh-air flow and the filtration are set after the survey, not from a copied model.

Air-handling units lined up in a plant room, with ducts above them.
  • Access door and control of an air-handling unit.
  • Square ceiling diffuser, with exposed pipes below.
  • Supply grille in the ceiling of a care room.

Services

Three subjects. The building says which ones are really in play.

Air-handling units

The unit brings together the fan, the filters and, when needed, the coils that heat or cool the fresh air.

Filtration

Filters hold back part of the dust. They are chosen for the room and the outdoor air, and a way to change them is planned.

Fresh air

The intake is placed away from exhausts, kitchen hoods and dusty roads.

Decided on site

What keeps three networks from being mixed up.

Not a split

Cooling a room and treating fresh air are two needs. One can exist without the other.

Not smoke control

A comfort unit does not replace a network meant for smoke.

Reachable filters

Without a hatch and room to pull the filters out, the system clogs and can no longer be maintained.

How it proceeds

The unit is installed once the intake and the duct route are known.

  1. 1. Site visit

    See the volumes, the possible air intake and the exhausts already in place.

  2. 2. Study

    Set the fresh-air flow and the filtration from the building, not from a neighbouring city.

  3. 3. Installation and commissioning

    Install the unit and the ducts, then check the direction of the air.

  4. 4. Maintenance

    Show how the filters are changed, and leave that access clear.

Common questions

Is this ventilation?

Ventilation renews the air. Air handling goes further: a unit filters that air and can heat or cool it. The two pages complement each other. They do not say the same thing.

Is this smoke control?

No. Smoke control is a safety network for smoke. A comfort unit does not do that job.

What filtration is used?

It depends on the room and the outdoor air: humidity on the coast, dust in Marrakech or near a building site. A filter is not fixed before the survey.

Where does the unit go?

In a plant room, a ceiling void or on the roof, where ducts can leave and filters can still be changed. Access is part of the study.

Which areas are covered?

Casablanca, Mohammedia, Bouskoura, Tamaris, Zenata, Rabat and Marrakech. The outdoor air is not the same in each. The intake is judged on site.

How do I ask for a visit?

Give the city and the type of premises on the contact page, or write on WhatsApp. The visit is to see the intake and the duct route.

Talk about the project

Tell us the city, the district and the type of home. A technician arranges a visit to see the place.